GD-3536A Open cup flash point laboratory equipment
-
USD51-1 Piece/Pieces
-
USD1≥2 Piece/Pieces
- Payment Type:
- L/C, T/T, Western Union
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 1 Piece/Pieces
- Min. Order:
- 1 Piece/Pieces
- Delivery Time:
- 7 Days
- Transportation:
- Ocean, Land, Air
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | ChongQing,China |
---|---|
Productivity: | 50piece/Month |
Supply Ability: | 50Piece/Month |
Payment Type: | L/C,T/T,Western Union |
Incoterm: | FOB,CFR,CIF |
Transportation: | Ocean,Land,Air |
Product Description
Product Description
Purpose
This GD-3536A Automatic Cleveland Open Cup Flash Point Meter is designed and made as per GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points- Cleveland open cup method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils.
Technical parameters
Model | GD-3536A Automatic Cleveland Open Cup Flash Point Meter | ||
Power supply | AC 220 V±10%, 50 Hz | ||
Temperature measurement | Full scale: Ambient temperature to 300 °C | ||
Repeatability: ≤8°C | |||
Reproducibility: ≤16°C | |||
Resolution: 0.1°C | |||
Precision: 0.5% | |||
Basic parameters | Temperature rising speed: as per GB/T3536 | ||
Ignition mode: by an electric flame (gas flame is 3 to 4 mm); | |||
Ambient temperature | 10~40°C | ||
Relative humidity | ≤80% | ||
Total power consumption | not more than 500 W |
Characteristics
1. This instrument adopts LCD screen to display and full English man-machine interface. It can preset expected flash point temperature, sample mark number, barometric pressure and other parameters.It has menu prompt and input guide. | |||
2. It adopts simulation tracking to display the function curve of temperature rising and test time. It has the functions of English mis-operation prompt,test date,test time and other parameters | |||
3. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value. | |||
4. Differential coefficient detection.Automatically correct the system deviation. | |||
5. Automatically open the lid,detect the flash point and print test data.The test arm automatically rise up and lower down. | |||
6. Beautiful design,safe and convenient to operate |