GD-0165 Best-selling Vacuum Distillation Unit at Reduced Pressure
-
USD51-1 Piece/Pieces
-
USD1≥2 Piece/Pieces
- Payment Type:
- L/C, T/T, Western Union
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 1 Piece/Pieces
- Min. Order:
- 1 Piece/Pieces
- Delivery Time:
- 7 Days
- Transportation:
- Ocean, Land, Air
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | ChongQing,China |
---|---|
Productivity: | 50piece/Month |
Supply Ability: | 50Piece/Month |
Payment Type: | L/C,T/T,Western Union |
Incoterm: | FOB,CFR,CIF |
Transportation: | Ocean,Land,Air |
Product Description
Product Description
I. Introduction
- GD-0165 ASTM D1160 Vacuum Distillation Analyzer is designed and made as per the industrial standard of People's Republic of China SH/T0165-92 Test Method for Distillation of High Boiling Point of Petroleum Products at Reduced Pressure.
- GD-0165 ASTM D1160 Vacuum Distillation Analyzer is suitable to determine the distillation characteristics of high boiling point petroleum products, such as wax oils, lubricating oils, etc.
II. Main Technical Features
- GD-0165 ASTM D1160 Vacuum Distillation Analyzer is desktop structure. It is composed of distillation test part and vacuum process part. It can meet requirements of SH/T 0165
- The power of the heating furnace can be adjusted continuously. It equips a cooling device to make the heating furnace cooled down rapidly after determination. It is convenient for next test.
- The vacuum pump has good effect. The max residual pressure is 2mmHg.
Ⅲ. Main Technical Specification
1 |
Power supply
|
AC 220 V±10%, 50 Hz
|
2 |
Heating power
|
Heater for distillation flask: 1000 W
|
Heater for receiving flask: 350 W
|
||
3 |
Heating power for distillation flask
|
0W to 1000 W, adjustable
|
4 |
Temperature range for air bath of receiving flask
|
room temperature to 100 ℃,adjustable.
|
5 |
Temperature sensor of air bath
|
Pt100,RTD
|
6 |
Temperature control mode for air bath
|
Digital temperature controller
|
7 |
Temperature controlling precision
|
Set temp. ±1 ℃
|
8 |
Valume of buffer vessel
|
1000 ml
|
9 |
Max. Residual pressure of vacuum pump
|
2 mmHg
|
10 |
Illumination light in the air bath of receiving flask
|
Energy saving lamp
|
11 |
Working condition
|
Ambient temperature: 5℃ to 35 ℃ Relative humidity: ≤85%
|
IV. Packaging List of GD-0165 ASTM D1160 Vacuum Distillation Analyzer
No.
|
Name | Unit | Quantity | Remark |
1 | Main unit | Set | 1 | |
2 | Vacuum pump (2 L) | Set | 1 | ZXZ-2 |
3 | Distillation flask | Piece | 1 | |
4 | Receiving flask | Piece | 1 | |
5 | Thermometer (0 to 360 °C) | Piece | 1 | |
6 | Silica gel stopper (4#) | Piece | 1 | |
7 | Fuse of 10 A (Inner Dia.5×20) | Piece | 2 | |
8 | 6 (Outer diameter)×4 (Inner diameter) PU tube | Meter | 2 | Connect the pump to the instrument |
9 | 6 (Outer diameter)×4 (Inner diameter) PU tube | Meter | 0.4 | Connect U type tube to the instrument |
10 | Glass U type tube | Piece | 1 | |
11 | Syringe | Piece | 1 |
To fill mercury into the U type tube |