China Chongqing gold industry
China Chongqing gold industry
GD-3536 Hot Sale Flash Point & Fire Point Apparatus, ASTM D92 Flash Point & Fire Point Apparatus
  • GD-3536 Hot Sale Flash Point & Fire Point Apparatus, ASTM D92 Flash Point & Fire Point Apparatus
GD-3536 Hot Sale Flash Point & Fire Point Apparatus, ASTM D92 Flash Point & Fire Point Apparatus

GD-3536 Hot Sale Flash Point & Fire Point Apparatus, ASTM D92 Flash Point & Fire Point Apparatus

  • USD5
    1-1 Piece/Pieces
  • USD1
    ≥2 Piece/Pieces
Payment Type:
L/C, T/T, Western Union
Incoterm:
FOB, CFR, CIF
Min. Order:
1 Piece/Pieces
Min. Order:
1 Piece/Pieces
Delivery Time:
7 Days
Transportation:
Ocean, Land, Air
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: ChongQing,China
Productivity: 50piece/Month
Supply Ability: 50Piece/Month
Payment Type: L/C,T/T,Western Union
Incoterm: FOB,CFR,CIF
Transportation: Ocean,Land,Air
Product Description
Product Description

GD-3536 Cleveland Open-Cup Flash Point Tester

Introduction:
This instrument is designed and made as per standards GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland Open Cup Method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79℃ and below 400℃ except fuel oils.
 
Features:
1. It adopts special heating furnace to ensure the safety of test. The heating power is continuously adjustable. It can meet requirements of test.
2. The instrument adopts desktop structure. The stainless steel working table and furnace shell make it beautiful and elegant.
3. The instrument is fully self-contained complete. The operator can do determination as long as connecting with coal gas or other civil gas.
4. It equipped with flame extinguishing cover which accord with requirements of test.
 
Specifications:
Power supply   AC(220±10%)V, 50Hz
Heating device Quartz tube furnace heating, no naked fire, explosion prevented. The power is adjustable from 0W to 600W
Test flame applicator
 
It applies the test flame automatically
Thermometer (-6~400)℃. It is the same as thermometer ASTM 11C
Igniting device (1) Ignition source: coal gas(or civil gas)
(2) Flame diameter is 3.2mm-4.8mm
Ambient temperature (-10~50)℃
Relative humidity ≤85%
Maximum power consumption 650W
Dimension 350*290*350mm (thermometer is not included)
 



Power supply AC 220 ± 10 %, 50 Hz.
Heating power 1000W(auxiliary heating), 600W(temperature control heating)
Stirring motor 6 W, 1200 RPM
Temperature range Ambient to 100.0℃.
Temperature control accuracy ±0.01℃
Timer 0.0s~999.9s
Constant temperature bath 20L, double shall structure
Ambient temperature -10℃~+35℃
Relative humidity <85%
Maximum power consumption. 1800W
Capillary viscometer tubes(Pinkevitch viscometer) 7 pieces in total. The inner diameters for each: 0.6, 0.8,1.0, 1.2, 1.5, 2.0 and 2.5mm
Dimension 530*400*670mm(Bath is included)


  


Send your message to this supplier