China Chongqing gold industry
China Chongqing gold industry
GDYJ-502 Insulating oil Dielectric Strength Test set ( BDV Test)
  • GDYJ-502 Insulating oil Dielectric Strength Test set ( BDV Test)
GDYJ-502 Insulating oil Dielectric Strength Test set ( BDV Test)

GDYJ-502 Insulating oil Dielectric Strength Test set ( BDV Test)

Payment Type:
T/T, L/C, D/A
Incoterm:
FOB
Min. Order:
1 Set/Sets
Min. Order:
1 Set/Sets
Delivery Time:
20 Days
Transportation:
Ocean, Land, Air
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Chongqing
Payment Type: T/T,L/C,D/A
Incoterm: FOB
Certificate: CE SGS
Transportation: Ocean,Land,Air
Product Description
Product Description

GDYJ-502 Transformer Oil Puncture Voltage Test Kit, Oil BDV Test


Standard

  • 1.IEC6015/IEC6792/BS5874
  • 2.ASTM D1816 standard test
  • 3.ASTM D877 standard test
  • 4.GB-86 Insulating Oil Dielectric Strength Testing Method

General introduction

  • 1.GDYJ-502 Transformer Oil dielectric testing equipmentis developed according to the national standard GB86 Insulating Oil Dielectric Strength Testing Method .
  • 2.LCD screen can display test procedure and test result.
  • 3. All the human interaction operations complete by the rotating mouse .
  • 4.With the micro printer internal the tester.
  • 5.With RS232 PC port for data analyzing.
  • The special circuit design makes the tester has a good performance at stability and anti-noise.

Functions

  • 1 Breakdown test of user-defined
  • 2 Proof test
  • 3 IEC156/IS6792/BS5874/
  • 4 ASTM D1816 standard test
  • 5 ASTM D877 standard test
  • 6 5 minutes standard test
  • 7 Manual test
  • 8 Calibration interface for customers
  • 9 Unloading data to PC and making word report automatically.
  • 10 Result print

Technique index

1 Output voltage:AC 0V~100KV

2 Rate of voltage rise: 0.5kv/s±5%, 2kv/s±5%, 3kv/s±5%,5kv/s±5%

3 Max test times setting for user-defined mode: 9

4 Stir time setting for user-defined mode: 0~999s

5 Waiting time setting for user-defined mode: 0~999s

6 Test error: 3%RDG+0.3%FS

7 Display: 256*128 LCD

8 Maximum storage capacity: 100 groups of test data

9 Power supply : AC220V±10%, 50Hz/60Hz

10 Environment temperature: 0-50°C

11 Relative humidity ≤80%RH