chongqing gold mechanica& electrical equipment co.,ltd
chongqing gold mechanica& electrical equipment co.,ltd
GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester
  • GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester
GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester

GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester

Payment Type:
T/T, L/C, D/A
Incoterm:
FOB
Min. Order:
1 Set/Sets
Min. Order:
1 Set/Sets
Delivery Time:
7 Days
Transportation:
Ocean, Land, Air
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: chongqing
Productivity: 1000 sets per year
Payment Type: T/T,L/C,D/A
Incoterm: FOB
Certificate: ISO
Transportation: Ocean,Land,Air
Product Description
Product Description
The instrument is designed and made as per the National Standard of People`s Republic of China GB/T5208 [Test Methods for Flash Point (Rapid Equilibrium Closed Cup Method)". It can be used in the field of petroleum, chemistry, paints, railway, aviation, power plant, inspection, military, and scientific research to determine flash point of petroleum products rapidly.
The instrument is suitable to make closed cup flash point determination for paints, adhesives, solvents, petroleum, and relative petroleum products, the flash points of which are in the range of 30℃~50℃. It can also meet the requirements of ISO 1523 and ISO 3679.

I. Main technical characteristics
1. It is designed as per GB/T5208 (Test Methods for Flash Point (Rapid Equilibrium Closed Cup Method)". It can determine closed cup flash point at a low temperature rapidly.
2. It adopts semiconductor refrigeration device and cooling water refrigeration device. It is small, convenient and with rapid refrigeration speed.
3. It needs fewer samples. The sample for each test is only 2 ml (For solid or semisolid sample, it is 4 ml);
4. The test can be automatically completed excepting flame ignition. The test data can be automatically printed.

II. Main technical specification and parameters
1. Power supply: AC 220V±10%, 50 Hz;
2. Flash point measurement range: -30~50℃;
3. Measurement accuracy:
(1) Repeatability: less than 2℃;
(2) Reproducibility: less than 2℃;
4. Temperature controlling accuracy: ±0.5℃;
5. Igniter: an electron igniter;
6. Refrigeration type: It uses semiconductor for refrigeration (It connects to outer cooling water);
7. Power supply: AC 220V±10%, 50 Hz;
8. Total power consumption: not more than 300 W;
9. Ambient temperature: 5℃~30℃;
10. Relative humidity: 30~80%;