Resistivity Meter, Geophysical Equipment, Geological Survey Instrument, Underground Explocation, Ground Water Detector, Water Finder
- Payment Type:
- L/C, T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
Product Description
Ground Resistivity Meter For Ground Water Detector
Main Applications and Features
By utilizing the apparent resistivity parameters, it is widely used in hydrology, environmental protection, engineering geophysical exploration, metal and non-metal mineral resources exploration.
Microcomputer controlled, direct-reading resistivity, various electrode arranging mode, data protection against power-failure
This instrument applies to Electrical Prospecting such as Vertical Electrical Sounding, Electrical Profiling, Charging Method and Spontaneous Potential Method, etc. On ground and in trench.
Technical Specifications
Maximum Power Supply Voltage: 700V
Maximum Power Supply Current: 3A
Voltage Measuring Range: ± 3000mV?
Voltage Measurement Accuracy: ± 1.5%, ± 0.1 mV
Current Measuring Range: 0.1mA~3000mA
Current Measurement Accuracy: ± 1.5%, ± 0.1mA
SP Compensation Range: -1000mV ~ +1000mV
Instrument Input Impedance: >30MΩ
Working Temperature: -10° C~50° C
Volume: 244× 154× 237mm
1. Ground Unit In English
2. Electrode for Measurement
3. Connections of working
Main Applications and Features
By utilizing the apparent resistivity parameters, it is widely used in hydrology, environmental protection, engineering geophysical exploration, metal and non-metal mineral resources exploration.
Microcomputer controlled, direct-reading resistivity, various electrode arranging mode, data protection against power-failure
This instrument applies to Electrical Prospecting such as Vertical Electrical Sounding, Electrical Profiling, Charging Method and Spontaneous Potential Method, etc. On ground and in trench.
Technical Specifications
Maximum Power Supply Voltage: 700V
Maximum Power Supply Current: 3A
Voltage Measuring Range: ± 3000mV?
Voltage Measurement Accuracy: ± 1.5%, ± 0.1 mV
Current Measuring Range: 0.1mA~3000mA
Current Measurement Accuracy: ± 1.5%, ± 0.1mA
SP Compensation Range: -1000mV ~ +1000mV
Instrument Input Impedance: >30MΩ
Working Temperature: -10° C~50° C
Volume: 244× 154× 237mm
1. Ground Unit In English
2. Electrode for Measurement
3. Connections of working
Related Keywords