Gdgs Tan Delta Automatic Dielectric Loss Tester
- Payment Type:
- L/C, T/T, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Chongqing, China |
---|---|
Payment Type: | L/C, T/T, Western Union |
Product Description
Product Description
GDGS Automatic Dielectric Loss Tester
I Brief Introduction
GDGS Automatic Dielectric Loss Tester is applied to meaure the dielectric loss and capacitor value of insulating materials.
GDGS Automatic Dielectric Loss Tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That make the tester has a good performance in measurement precision.
II Main Parameter
ModelGDGS Automatic Dielectric Loss Tester
Condition of Use-5° C~40° C, RH<80%
Power SourceAC 110V± 10% Without Frequency Limit
High Voltage Output Range1KV~10KV, every 1KV
Precision5%
Maximum Current140mA
Capacity1000VA
Self-Excited Power
Voltage RangeAC 0V~30V
Frequency45Hz /55Hz
Maximum Current15A
Output voltageAC 0.5KV~10KV
Testing voltage setting resolution0.5KV
Maximum output capacity200mA
Testing frequency45Hz/55Hz
Test modefully automatic
Power supplyAC220V± 50Hz/60Hz%10%
Environment temperature0-50° C
Humidity≤ 85%RH
Weight40KG
III Packing∇ivery
Payment & Shipping Terms
Supply Capacity
Payment term:
T/T or L/C
Production capacity:
500pcs/month
MOQ:
1 pc
Packing:
Wooden case
Price
Negotiable
Delivery way
By Air
Means of transport:
FOB, CIF, CFR
Delivery time:
10 days
I Brief Introduction
GDGS Automatic Dielectric Loss Tester is applied to meaure the dielectric loss and capacitor value of insulating materials.
GDGS Automatic Dielectric Loss Tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That make the tester has a good performance in measurement precision.
II Main Parameter
ModelGDGS Automatic Dielectric Loss Tester
Condition of Use-5° C~40° C, RH<80%
Power SourceAC 110V± 10% Without Frequency Limit
High Voltage Output Range1KV~10KV, every 1KV
Precision5%
Maximum Current140mA
Capacity1000VA
Self-Excited Power
Voltage RangeAC 0V~30V
Frequency45Hz /55Hz
Maximum Current15A
Output voltageAC 0.5KV~10KV
Testing voltage setting resolution0.5KV
Maximum output capacity200mA
Testing frequency45Hz/55Hz
Test modefully automatic
Power supplyAC220V± 50Hz/60Hz%10%
Environment temperature0-50° C
Humidity≤ 85%RH
Weight40KG
III Packing∇ivery
Payment & Shipping Terms
Supply Capacity
Payment term:
T/T or L/C
Production capacity:
500pcs/month
MOQ:
1 pc
Packing:
Wooden case
Price
Negotiable
Delivery way
By Air
Means of transport:
FOB, CIF, CFR
Delivery time:
10 days
Related Keywords
Related Keywords
You May Also Like
You May Also Like