Dissipation Factor Instrument, Power Factor Tester
- Payment Type:
- L/C, T/T, Money Gram
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Chongqing |
---|---|
Payment Type: | L/C, T/T, Money Gram |
Product Description
Product Description
1. Features
GDGS Dissipation Factor(Power Factor) Tester is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test. The set is whole in one designed: Including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits.
It's also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it's running automatically and then outputs the results on LCD display and prints the results automatically.
1.1 Specifications
Accuracy: Cx ± (reading× 1%+1pF)
PF ± (reading× 1%+0.00040)
Interference Ratio: Interference current is no more than 2 times of the test current
Capacitance Range: Internal HV 3pF~60000pF / 10kV, 60pF~1uF/0.5kV
External HV 3pF~0.3uF/10kV
Resolution 0.0001pF, 4 digital
PF Range: No limit, Resolution 0.001%, C/L/R specimen test
Input current range: 10μ A~1A
Internal HV: 0.5~10kV / 200mA (max)
HV Adjust: Rise or fall smoothly
HV Accuracy: ± (reading× 1%+10V) Resolving 1V
Frequency select: 60Hz single point, locked
55Hz/65Hz double point, locked
Test Time: 40S typical
Power Supply: 180V~270V 50Hz/60Hz auto
Operating Temperature: 0° C~60° C
Storage Temperature: -20° C~60° C
Humidity: <90%
Pacakging
GDGS Dissipation Factor(Power Factor) Tester is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test. The set is whole in one designed: Including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits.
It's also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it's running automatically and then outputs the results on LCD display and prints the results automatically.
1.1 Specifications
Accuracy: Cx ± (reading× 1%+1pF)
PF ± (reading× 1%+0.00040)
Interference Ratio: Interference current is no more than 2 times of the test current
Capacitance Range: Internal HV 3pF~60000pF / 10kV, 60pF~1uF/0.5kV
External HV 3pF~0.3uF/10kV
Resolution 0.0001pF, 4 digital
PF Range: No limit, Resolution 0.001%, C/L/R specimen test
Input current range: 10μ A~1A
Internal HV: 0.5~10kV / 200mA (max)
HV Adjust: Rise or fall smoothly
HV Accuracy: ± (reading× 1%+10V) Resolving 1V
Frequency select: 60Hz single point, locked
55Hz/65Hz double point, locked
Test Time: 40S typical
Power Supply: 180V~270V 50Hz/60Hz auto
Operating Temperature: 0° C~60° C
Storage Temperature: -20° C~60° C
Humidity: <90%
Pacakging