Gd-4530f Laboratory Analyzer Atomic Absorption Spectrophotometer
- Payment Type:
- L/C, T/T, D/P
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Chongqing |
---|---|
Payment Type: | L/C, T/T, D/P |
Product Description
Product Description
Characteristics
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
4. Position adjusting: The best height of the flame burner and can automatically set the front and rear positions
5. Fully automated wavelength scanning and peak searching
6. Complete safety chains protection equipment: The function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
7. Deuterium lamp and self-absorption background regulation
8. Data processing: Super strong database, possesses more than 500 data selfstorage and cutoff storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called
9. Measuring method: Flame absorption method and emission method
10. Result printing: Parameter printing, data result printing and diagram printing
Complete automatic controlling system
With the help of the software, the following can be easily achieved
1. Selection of the element lamp
2. Up-down-front-rear adjustment of the lifter
3. Adjustment of the optical energy
4. Selection of the slit
5. Determination of wavelength scanning and peak searching
6. Selection of the atomizer
7. Setting of the background deduction method
8. Controlling of the gas flow
9. Automatic flaming and flaming out
10. Setting of the graphite furnace testing method
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
4. Position adjusting: The best height of the flame burner and can automatically set the front and rear positions
5. Fully automated wavelength scanning and peak searching
6. Complete safety chains protection equipment: The function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
7. Deuterium lamp and self-absorption background regulation
8. Data processing: Super strong database, possesses more than 500 data selfstorage and cutoff storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called
9. Measuring method: Flame absorption method and emission method
10. Result printing: Parameter printing, data result printing and diagram printing
Complete automatic controlling system
With the help of the software, the following can be easily achieved
1. Selection of the element lamp
2. Up-down-front-rear adjustment of the lifter
3. Adjustment of the optical energy
4. Selection of the slit
5. Determination of wavelength scanning and peak searching
6. Selection of the atomizer
7. Setting of the background deduction method
8. Controlling of the gas flow
9. Automatic flaming and flaming out
10. Setting of the graphite furnace testing method