This instrument is designed and made as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method.
It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil, chemical, varnish, paint, railway, aviation, electricity, commercial inspection and science research institution.
This instrument is specially suitable to determine different kinds of colored paints, oil paints, adhesives, solvents and petroleum products which the closed cup flash point is 50° C~100° C.
The instrument is also correspond with ISO1523 and ISO3679.
II---Main technical features
1. Designed as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can realize purpose of testing closed cup flash point rapidly and at low temperature.
2. The instrument adopts semiconductor refrigeration device and external water cooling device. The size is small and cooling rate is rapid. Easy to operate.
3. Test sample needed is less. 2ml for each time(4ml for solid sample and semi-solid sample)
4. The determination procedure is automatically completed except ignition. Test results can be printed automatically.
III---Main technical specifications and parameters
1. Power supply: AC(220± 10%)V, 50Hz
2. Flash point detecting range: (50~100)° C
3. Precision of determination:
Absolute difference value between two determinations is lower than 2° C(same operator)
Absolute difference value between two determinations is lower than 3° C(different operator)
4. Accuracy of temperature control: ± 0.5° C
5. Igniting device: Electric igniting gun
6. Cooling mode: Semiconductor(with cold water cycle at external connection)
7. Overall Power Consumption: Not higher than 300W
8. Ambient temperature: (5~30)° C
9. Relative humidity: (30~80)%
10. Overall dimension: 370mm× 280mm× 280mm(L× W× H)