Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Gd-510d Pour Point&Cloud Point Tester for Petroleum Oils
  • Gd-510d Pour Point&Cloud Point Tester for Petroleum Oils
Gd-510d Pour Point&Cloud Point Tester for Petroleum Oils

Gd-510d Pour Point&Cloud Point Tester for Petroleum Oils

Payment Type:
L/C, T/T, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Chongqing of China
Payment Type: L/C, T/T, Western Union
Product Description
Product Description
GD-510D Pour Point&Cloud Point Tester for Petroleum Oils

I. Description
1. GD-510D Pour Point&Cloud Point Tester is designed and made as per the National Standard GB/T3535 "Test Methods for Pour Point of Petroleum Products", and GB/T6986 "Test Methods for Cloud Point of Petroleum Products".
2. GD-510D Pour Point&Cloud Point Tester is suitable to determine pour point and cloud point of petroleum products. It is also suitable to determine pour point and cloud point of petroleum products as per ASTM D97, ASTM D2500, IP15 & IP219.

II. Features of the pour point tester
1. The working table is stainless steel material. It has two cold troughs(trough I and trough II). Each trough equipped two
Baths. The temperature of these two baths are equal. All the baths can do determination of pour point and cloud point.
2. It is no need to use coolant in the trough. The cooling speed is fast and cooling efficiency is high. The temperature
ControllerI controls the temperature of trough I and temperature controller II controls the temperature of trough II. The minimum temperature of trough II can reach -70° C and temperature control accuracy can reach ± 1° C.
3. The instrument adopts desktop structure, concise design and easy to use.

III. Specifications of the pour point tester
1. Power supply: AC 220 V± 10%, 50 Hz;
2. Temperature controlling range of cold trough:
(1) Cold trough I: Room temperature~-51 ° C, ± 1 ° C, the temperatures of two baths are equal.
(2) Cold trough II: Room temperature~-70 ° C, ± 1 ° C, the temperatures of two baths are equal.
3. Refrigeration system: A refrigeration compressor of new type
4. Ambient temperature: ≤ 30 ° C
5. Relative humidity: ≤ 85%
6. Power consumption: ≤ 1500 W
7. Overall dimension: 800mm× 580mm× 400mm

IV. More low temperature tester

Send your message to this supplier

  • Ms. Ivy Zhang

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords