Gd-0613A Fraass Method Asphalt Breaking Point Tester
- Payment Type:
- L/C, T/T, Money Gram, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Chongqing, China |
---|---|
Payment Type: | L/C, T/T, Money Gram, Western Union |
Product Description
Product Description
GD-0613A Asphalt Breaking Point Tester( Fraass Method)
I---Purpose:
GD-0613A Breaking Point of Bituminous Binders-Fraass Method-BPA is designed and made as per T0613 "Asphalt Breaking Point Test (Fraass Methods) in the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous Mixture for Highway Engineering. It is suitable to determine Fraass Breaking Point of bituminous materials.
Breaking Point of Bituminous Binders-Fraass Method-BPA can make determination for 3 pieces of samples at the same time, and calculate the average value of three test data. The instrument uses computer to control cooling rate and the instrument is equipped with a printer to print out test data and a RS232 output port.
II---Technical parameters
1. Power supply: AC 220V± 10%, 50 Hz;
2. Cooling mode: By water;
3. Cooling rate: 1° C± 0.5° C/min;
4. Temperature measurement range: -27° C~25° C;
5. Temperature measurement error: ± 0.5° C;
6. Size of steel sheet: 41× 20× 0.15(mm);
7. Sample quantity: It can make determination for 3 pieces of samples at the same time;
8. Ambient temperature: Room temperature~+30° C;
9. Relative humidity: ≤ 85%;
10. Total power consumption: Not more than 450 W
I---Purpose:
GD-0613A Breaking Point of Bituminous Binders-Fraass Method-BPA is designed and made as per T0613 "Asphalt Breaking Point Test (Fraass Methods) in the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous Mixture for Highway Engineering. It is suitable to determine Fraass Breaking Point of bituminous materials.
Breaking Point of Bituminous Binders-Fraass Method-BPA can make determination for 3 pieces of samples at the same time, and calculate the average value of three test data. The instrument uses computer to control cooling rate and the instrument is equipped with a printer to print out test data and a RS232 output port.
II---Technical parameters
1. Power supply: AC 220V± 10%, 50 Hz;
2. Cooling mode: By water;
3. Cooling rate: 1° C± 0.5° C/min;
4. Temperature measurement range: -27° C~25° C;
5. Temperature measurement error: ± 0.5° C;
6. Size of steel sheet: 41× 20× 0.15(mm);
7. Sample quantity: It can make determination for 3 pieces of samples at the same time;
8. Ambient temperature: Room temperature~+30° C;
9. Relative humidity: ≤ 85%;
10. Total power consumption: Not more than 450 W