(ZYD) Double Stage Vacuum Transformer Oil Regeneration Machine with CE Standard
- Payment Type:
- L/C, T/T
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Chongqing, China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Specifications
1 Suit for 1000KV, 800KV, 750KV, 660K projects
2 Remove water, gas, particles
(ZYD)Double Stage Vacuum Transformer Oil Regeneration Machine With CE Standard
Product Description
As is well known the Transformer plays an important role in the generation, transmission and distribution of
electrical energy. Under load the transformer, dissipates heat and the insulating oil acts as a coolant as well
as an effective dielectric.
Due to the highly hygroscopic nature of the transformer oil, it absorbs moisture from windings, which leads to
gradual deterioration of dielectric strength. Also there are some waste impurities, gas contents in the transformer oil which destroy the oil's quality.
TOP oil purifier is the most efficient and economical purification system.
This oil purification plant is applied to filter various of unqualified insulation oils including aging transformer oil
specially for the power which is above 110KV, mutual inductor oil, switch oil and so on. Also it can inject the
insulating oil into the transformers on-line.
Features:
1. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
2. UK G technology by which the trace water that is show chain, such as dissolved water, can be removed ffectively.
3. Distinctive removing impurities system filtering through double FH trapezoidal network and absorbing by high polymer without the mechanical power
4. Carbon fiber infrared heating system that can make the oil contains zero sum of ethyne after the treatment
5. Especially applied to vacuum oiling and drying for power transmission equipments which are over 110KV
6. The oil of any grades can be treated on line at the working site.
7. Can be operated both on-load and off-load.
8. Can be operated fully-automatically with PLC controller.
9. this Oil purifier can be made in hermetical, canopy-covering, open and frame style.
Advantages:
this machine dewater, degas and removes the impurities more quickly, more completely, and makes the oils
limiting voltage-withstand value much higher. As the bridge-type vacuum linking system that can purify and
also can be an independent vacuum power supply, this machine can treat the electric insulation devices.
Our oil filtration machine:
Series ZY Single-Stage Vacuum Transformer Oil Purifier
Series ZYD Double High Vacuum Transformer Oil Purifier
Series ZYB Multiply-Function insulating oil treatment machine
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light Fuel oil purification machine
Series TYD Vacuum dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series TYD Vacuum dehydrator
Series EFD Explosion protection filtration machine
Series BAM Press filtration system
Series ZKCC Vacuum pumping device
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series JL Portable oil filtering and oiling machine
Our oil tester/ analyzer:
Series IIJ-II Insulating oil breakdown strength tester(oil BDV tester)
Series HTJS-H Insulating oil dielectric tester (dielectric loss tester for insulating oil)
Series HTJS-V Tan-Delta Tester (anti-jamming dielectric loss tester for HV electrical equipment)
Series TP-3A Water content tester/ moisture sensor
Series TPV-8 Viscosity analyzer
Series TPC-2100 Flash point analyzer (close cup)
Series TPO-2100 Flash point analyzer (open cup)
Series CL-3 Interfacial tension analyzer
If you would like to know more about our oil purifiers and oil testers, please feel free to contact us any time. due to a sales as I, it is my biggest pleasure and responsibility to help my old and new clients to buy the high quality goods with best prices.
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow Rate | L/h | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working vacuum | MPa | -0.08 ~ -0.099 | |||||||
Working Pressure | MPa | ≤0.3 | |||||||
Temperature Range | °C | 20 ~ 80 | |||||||
Power | Three Phase 50Hz,380V (or as needed) | ||||||||
Working Noise | dB ( A ) | 70 | 70 | 70 | 75 | 75 | 75 | 75 | |
Heating Power | KW | 28 | 30 | 45 | 60 | 75 | 90 | 120 | |
Total Power | KW | 35.5 | 37.5 | 52.5 | 71.4 | 86.5 | 102.5 | 135 | |
Inlet/Outlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 | |
Weight | Kg | 600 | 800 | 1050 | 1400 | 1800 | 2000 | 2200 | |
Overall | Length | mm | 1050 | 1100 | 1200 | 1450 | 1600 | 1800 | 1900 |
Width | mm | 750 | 800 | 950 | 950 | 1100 | 1200 | 1200 | |
Height | mm | 1350 | 1400 | 1500 | 1650 | 1800 | 1900 | 1900 |
Guarantee Value
Item | Unit | After treatment |
Breakdown Voltage | kV | ≥75 |
Moisture content | PPM | ≤3 |
Gas content | % | ≤0.1 |
Impurity size | micron |
≤0.5 (no free carbon) |