Galvanized Steel Wire Strands with Class B Insulation Grade, Used to Fix and Tie Hanging Systems
  • Galvanized Steel Wire Strands with Class B Insulation Grade, Used to Fix and Tie Hanging Systems
  • Galvanized Steel Wire Strands with Class B Insulation Grade, Used to Fix and Tie Hanging Systems
Galvanized Steel Wire Strands with Class B Insulation Grade, Used to Fix and Tie Hanging Systems
Galvanized Steel Wire Strands with Class B Insulation Grade, Used to Fix and Tie Hanging Systems

Galvanized Steel Wire Strands with Class B Insulation Grade, Used to Fix and Tie Hanging Systems

Payment Type:
T/T or L/C at Sight
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T or L/C at Sight
Product Description
Product Description
  • Aerial earth wire for BS 183, ASTM IEC 888 1 x 7, 1 x 19 and 1x 37
  • As overhead ground (or static) wire for protection againstlighting
  • 1 x 7 construction strand with grade A galvanization and withgroup one tensile strength is mostly used for thisapplications
  • Strand installed at the top of steel tower and functions as aground (earth) wire to protect the aluminum conductor with steelreinforced (ACSR) from lightening
  • With its normal lifespan of 20 to 30 years, thick galvanizedlayer better than or equivalent to that of galvanized strand forACSR is recommended
  • For telecommunication cables (self-supporting type)
  • Used to support self-supporting (SS) telecommunication cable,which has replaced obsolete lead-plated cables
  • 1 x 7 strands with group one tensile strength and grade Agalvanization are widely used for this application
  • The telecoms cable and galvanized strands are coated togetherwith a poly-ethylene insulation
  • As messenger wire to support utility lines
  • Used at train railroads, streetcar lines and subway railroads,either 1 x 7 or 1 x 19 construction strands are used as guying wire(for poles and towers)
  • Used as guying wire for various poles, towers for power andtelecoms cables, the industry is moving towards using higherstrength strands with better corrosion protection for thisapplications
  • Used for ACSR (aluminum conductor steel reinforced)
  • Used to support ACSR cable as the core strength member, forpower cables with above 60kV capacity, ACSR is widely used inreplacement of hard cu-strand conductors, in comparison with hardCu cables, ACSR weighs 20% less with 1.7 times increase in strengthso that the interval between power transmission towers can bedoubled