High Accuracy Fluorescence Spectrophotometer with Factory Price (GD-96 )
-
USD1≥1 Set/Sets
- Payment Type:
- L/C, T/T, D/P, Paypal, Money Gram, Western Union
- Incoterm:
- FOB
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Delivery Time:
- 5 Days
- Transportation:
- Ocean, Land, Air
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | Chongqing, China (Mainland) |
---|---|
Productivity: | 300 Set/Sets per Month |
Supply Ability: | 300 Set/Sets per Month |
Payment Type: | L/C,T/T,D/P,Paypal,Money Gram,Western Union |
Incoterm: | FOB |
Certificate: | CE |
Transportation: | Ocean,Land,Air |
Fluorescence analysis is a high sensitive and high selective sophisticated analytical method. This method can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence etc. This method can provide a wide lineal range of working curve. It has becoming an important analytical method in the region of trace analysis.
This method has been used in:
1. Medical science and clinical analysis Clinical analysis of biological specimen.
2. Pharmaceutical science and pharmacology Analysis of natural pharmaceutical products; Quality control of
pharmaceuticals and research of pharmaceutical metabolites.
3. Biochemistry Analysis of minute quantity of substances in biological body.
4. Food industry Analysis of minute quantity of constituents in food.
5. Pollution analysis Atmospheric pollution, environmental testing and food contamination analysis.
6. Organic and inorganic chemistry Used in the trace analysis in case of those substances cannot be determined by absorption spectrophotometry.
◆ Light source:Hamamatsu 150W Xenon lamp
◆ Exciting optical filters:Interference optical filter
* Standard set is equipped with an interference optical filter of central wavelength at 365nm and 10nm bandwidth
* An optional interference optical filer of 25mm diameter of wavelength of 250-700 nm can be provided on users
demand.
◆ Emission monochromator:C-T diffraction grating(Em 200~900nm,bandwidth 10nm)Wavelength accuracy±1nm
Wavelength repeatability ≤0.5nm
◆ Sensitivity:Raman peak of water in 1 cm quartz fluorescence cuvette with S/N≥150
◆ Linear measurement(r): ≥0.995
◆ Stability: better than 1.5%/10min
◆ Variation of power source: 220V±22V 50Hz±1Hz
◆ Response time: (0.1-4)s 6 stages adjustable