Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
Pensky-Martens Closed Cup Flash Point Tester
  • Pensky-Martens Closed Cup Flash Point Tester
Pensky-Martens Closed Cup Flash Point Tester

Pensky-Martens Closed Cup Flash Point Tester

Payment Type:
L/C, T/T
Incoterm:
FOB
Min. Order:
1 Set/Sets
Min. Order:
1 Set/Sets
Delivery Time:
10 Days
Transportation:
Ocean, Land, Air
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: L/C,T/T
Incoterm: FOB
Transportation: Ocean,Land,Air
Product Description
Product Description

Application

 

Gold GD-261A pensky-martensclosed cup  flash point tester is used to determine flash point of specimen under specified condition, by closed cup method. It is widely used in petroleum product industry, related education school, scientific research units and other related departments.
The flash point of a specimen is the lowest temperature at which it can vaporize to form an ignitable mixture in air. It is one measure of the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.

 

 

Standards

STANDARDS

ISO2719-2002

ASTM D93

GB/T 261-2008

Note: this tester can conform to but not limit to the standards above, for more standards conformance, please contact us.

 

 

 

Main technical specifications and parameters

 

 

Power supplyAC(220±10%)V, 50Hz
Temperature measurementMeasuring range: Room temperature~350°C
Test range of flash point: 41°C~350°C
Flash point104°C: error 2°C
Flash point>104°C: error 6°C
Accuracy: 0.1°C
Heating rateProcedure A: (5~6)°C/min
Procedure B:(1~1.6)°C/min
Stirring rateProcedure A: (90~120)RPM
Procedure B: (250±10)RPM
Igniting modeIgniting source: gas(or other civilian fuels,the same below)
Electric ignition. Gas flame diameter:3.2mm~4.8mm
Ambient temperature 40°C
Relative humidity 80%
Total power consumption 350W

 

 

 Main technical features

 

1. Simulation tracking displays function curves of heating up and test time.

2. Equipped with the English prompt function of mis-operation.

3. Equipped with prompt function of test date,test time and other parameters.

4. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.

5. Differential coefficient detection.Automatically correct the system deviation.

6. Automatically open the lid,detect the flash point and print test data.

7. The test arm rises up and lowers down automatically.

8. Igniting with electric igniting gun,forced air cooling.(GD-3536D Fully Automated PMCC Flash Point Tester has the funtion of automatic innition.)

 

Send your message to this supplier

  • Mr. Boswell

  • Enter between 20 to 4,000 characters.