Vacuum Transformer Oil Dehydration Machine, Oil Degassing
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Transportation:
- Ocean
- Port:
- Chongqing, Shanghai, Tianjin
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | China |
---|---|
Productivity: | 100 per week |
Supply Ability: | 100 per week |
Payment Type: | L/C,T/T |
Incoterm: | FOB,CFR,CIF |
Certificate: | ISO9001 & CE |
Transportation: | Ocean |
Port: | Chongqing,Shanghai,Tianjin |
Vacuum Transformer Oil Filtration Machine with Mobile Trailer and Metallic Doors
Application
Vacuum Transformer Oil Filtration Machine with Mobile Trailer and Metallic Doors is widely used in electric power, petroleum, chemical industry and railway etc for outdoor use. It can purify oil in fieldwork with additional installation of a trailer, a damping spring steel plate, a brake and cornering lamp, this guarantee the safety and reliability when moving in fieldwork.
It is also used for hot oil circulation drying and oil purification when various large transformer equipment installation and maintenance. Purifying insulating oil in 110KV-330KV transformer, also suitable for high grade new oil, imported oil deep purifying.
Features
1. Mobile (trailer) type, completely closed structure, waterproof, dust proof, easy to move.
2. can be designed for 3 wheels or 4 wheels to satisfy different needs of machine
3. Installation of car types, Bridge shock absorber, braking system and steel welding of entire trailer guarantee 60km/h speed.
4. Dealing with unqualified insulating oils, rapidly remove water, gas, particles from oil and improve oil BDV value highly.
5. Multi-stage precision filtration system, mesh filtration combined with molecular adsorption technologies
6. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable.
7. Double-infrared liquid level sensor, pressure protective system to ensure machine operation easy and safely.
8. Suitable for treating high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work on site.
9. Can be used as independent vacuum source with functions of vacuum drying and vacuum oiling.
10 1800-18000L per hour to meet different needs of flow rate.
Technical Parameters:
Parameters |
Unit |
ZYD-M-30 |
ZYD-M-50 |
ZYD-M-100 |
ZYD-M-150 |
ZYD-M-200 |
ZYD-M-250 |
ZYD-M-300 |
|
Flow rate |
L/min |
30 |
50 |
100 |
150 |
200 |
250 |
300 |
|
Working vacuum |
MPa |
0.08 ~ 0.099 |
|||||||
Working Pressure |
MPa |
≤0.3 |
|||||||
Temperature Range |
℃ |
20 ~ 80 |
|||||||
Power |
Three Phase 50HZ380V(as per the customer’s requirements) |
||||||||
Working Noise |
dB(A) |
75 |
75 |
75 |
80 |
80 |
80 |
80 |
|
Heating Power |
kW |
30 |
30 |
45 |
60 |
75 |
90 |
120 |
|
Total Power |
kW |
35.5 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 |
|
Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 |
|
Weight |
kg |
600 |
800 |
1050 |
1400 |
1800 |
2000 |
2200 |
|
Overall |
Length |
mm |
1050 |
1100 |
1200 |
1450 |
1600 |
1800 |
1900 |
Width |
mm |
750 |
800 |
950 |
950 |
1100 |
1200 |
1200 |
|
Height |
mm |
1350 |
1400 |
1500 |
1650 |
1800 |
1900 |
1900 |
Moisture |
PPM |
≤3 |
Gas content |
% |
≤0.01 |
Impurity size |
μ |
≤1 (no free carbon) |
Breakdown voltage |
kV |
≥75 |
IFT |
dynes/cm |
≥40 |
Acid value |
mgKOH/g |
≤0.03 |
Dielectric loss factors |
tgδ(90°C) |
≤0.001 |

Keywords:
transformer oil purifier, oil clean, oil reuse, oil recycle, transformer maintain, transformer service, transformer oil filter, insulating oil, breakdown voltage, water remove, gas remove, impurities in oil, aging oil treatment, transformer oil treatment