Chongqing TOP Oil Purifier Manufacture Co.,ltd
Chongqing TOP Oil Purifier Manufacture Co.,ltd
High Voltage Current transformer ratio tester series TPOM-901
  • High Voltage Current transformer ratio tester series TPOM-901
High Voltage Current transformer ratio tester series TPOM-901

High Voltage Current transformer ratio tester series TPOM-901

Payment Type:
T/T, L/C
Incoterm:
FOB
Min. Order:
1 Set/Sets
Min. Order:
1 Set/Sets
Delivery Time:
7 Days
Transportation:
Ocean, Land, Air
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Productivity: 300
Supply Ability: 200
Payment Type: T/T,L/C
Incoterm: FOB
Certificate: CE;ISO
Transportation: Ocean,Land,Air
Product Description
Product Description

Specifications

1.Current transformer ratio testing instrument
2.for three or singe phase transformer

High Voltage Current transformer ratio testing instrument series TPOM-901

1 Introduction

TPOM-901 is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a 320*240 LCD screen. All the test results could be printed by the micro printer or saved in the storage of the tester. The tester has a good performance on auto protection and anti-disturb.

2 Main functions

1. The voltage ratio measurement of three or singe phase transformer

2. The group vector measurement of three phase transformer.

3. The polarity measurement of single phase transformer or CT/PT

4. Voltage ratio error calculation

5. Voltage ratio range calculation of three phase transformer

6. Current transformer ratio measurement

7. Excitation current measurement in ratio testing

8. Reproduction the AC test voltage from power source to reduce the effects of bad power source

9. Save the test results in the memory internal the tester

10. Print the test results by micro printer

11. Reverse connection detect unit to prevent the high voltage injected to the operate

12. Over current protection in test voltage

13. Upload the test results to make word report by RS232 interface

3 Technique index

1. Ratio measurement range:1-10000

2. Group measurement:1-12

3. Phase measurement error:1 degree

4. Ratio measurement error:1-2000 ± 0.2% 2000-10000 ± 0.5%

5. Power supply:AC220V ± 10%, 50Hz

6. Size 400´350´200 mm3 Weight 7kg

Our Major Testing Equipment

1.Transformer oil breakdown voltage tester ( BDV test kit) series IIJ-II

2. Acidity tester model ACD-3000I

3. Karl Fischer water content tester model TP-6A / model TP-2100

4. Moisture content tester(TPEE)

5. Fully automatic interfacial tension analyzer model IT-800

6. Gas-chromatography transformer oil gas analyzer model DGA2013-1

7. Consolidation point determinator model PT-2000

8. Kinematic viscosity tester model VST-8 /model VST-2000

9. Flash point tester (open cup) model TPO-3000

10. Flash point tester (close cup) model TPC-3000

11. Transformer tester (CT/PT tester) model TPVA-404

12. Transformer turn ratio tester model HYG-II

13. Total base number analyzer(TBN tester) TBN-2030

Send your message to this supplier

  • Ms. Ewha

  • Enter between 20 to 4,000 characters.